A lightning protection system sits on the roof and down the walls for decades, mostly unnoticed. Tapes get disconnected during roof works, clamps corrode, test clamps go missing and earth electrodes dry out, and none of it is visible until a strike finds the weak point.

We inspect every air termination, down conductor, joint and test point, measure the earth resistance at each one, and issue a test certificate and report showing what passes, what doesn't and what to fix.

Earth resistance test on a lightning protection down conductor
Standards

Inspected against

  • BS EN 62305Protection against lightning, parts 1 to 4
  • BS EN 62305-3Physical damage to structures and life hazard
  • BS 7430Code of practice for protective earthing
  • BS 6651Withdrawn code of practice, still common on older installations
What we check

Inspection checklist

  • Air termination network and roof conductors
  • Down conductors and fixings
  • Joints, bonds and test clamps
  • Earth resistance at every test point
  • Continuity of the whole system
  • Bonding to roof plant and metalwork
  • Damage or changes since the last test
  • Test certificate and report
How it works

From building details to test certificate

  1. 1

    Send your site details

    The site address and the building size, or your last test certificate, is enough to price the job.

  2. 2

    Fixed quotation

    Priced per site, with multi-site estates grouped into efficient routes.

  3. 3

    Inspection & testing

    Every air termination, down conductor and earth inspected and tested on site.

  4. 4

    Certificate & report

    Test certificate, results per test point, photos of defects and the next test date.

FAQs

Common questions

How often should lightning protection be tested?

BS EN 62305-3 sets inspection intervals by protection level. Most UK sites test every year, and insurers often require it.

Do you test older BS 6651 systems?

Yes. Systems installed to the withdrawn BS 6651 are still tested, and we tell you where they fall short of BS EN 62305.

Will testing disrupt the building?

No. Testing is done from ground level and the roof without any interruption to power or occupants.